Experimental and modeling study of sulfur dioxide behavior during oxy combustion in fluidized beds

Liyong Wang
SO2 emissions from coal combustion have several harmful effects on the environment, including their contribution to acid rain. A variety of approaches have been developed to control SO2 pollution. Direct dry sorbent (limestone) injection is a relatively simple and low-cost process. Fluidized beds have been one of the most popular furnaces for the application of direct sorbent injection. In addition, oxy fuel combustion is a promising, practical method to reduce greenhouse gas emissions. Thus, studies...