Solutions for mid-rise wood construction: full-scale standard fire test for exterior wall assembly using a simulated cross-laminated timber wall assembly with interior fire-retardant-treated plywood sheathing (Test EXTW-4) (Report to research consortium for wood and wood-hybrid mid-rise buildings)

E. Gibbs, B.C. Taber, G.D. Lougheed, J.Z. Su & N. Bénichou
One of the tasks in the project, Wood and Wood-Hybrid Midrise Buildings, was to develop further information and data for use in developing generic exterior wall systems for use in mid-rise buildings using either lightweight wood frame or cross-laminated timber as the structural elements. This report describes a standard full-scale exterior wall fire test conducted on October 30, 2012 on a simulated cross-laminated timber (CLT) wall assembly with an attached insulated lightweight wood frame assembly...